C28/P16 Food Thermometer Kit
Part No: C28/P16 (3059089)The C28/P16 Food Thermometer Kit is a simple to use, food thermometer kit containing a C28 Type K Thermocouple Food Thermometer for reliable and accurate temperature measurement, as well as a PK19M Thin Tip Penetration Probe and a C20WB Wall Bracket/Stand.
- Temperature Range: -328°F to +1112°F / -200°C to +600°C
- Supplied with a PK19M Thin Tip Penetration Probe
- Durable Case with Built-In Protective Boot
- Warranty: see individual components
This product has a newer version Visit the upgraded version.
C28/P16 Food Thermometer Kit
The C28/P16 Food Thermometer Kit is a simple to use, food thermometer kit containing a C28 Type K Thermocouple Hand-Held Food Thermometer for reliable and accurate temperature measurement, as well as a PK19M Thin Tip Penetration Probe and a C20WB Wall Bracket/Stand.
Housed in a robust case with built-in protective rubber boot it can be used in a wide range of applications. Use with any Comark Type K probe with a sub-miniature connector.
- Large LCD display with permanent clock
- Auto switch-off conserves battery life
- Thermocouple sensor for high accuracy
- Durable poly-carbonate case
- Built-in protective boot
- BioCote Antimicrobial Protection
The C28 Food Thermometer is reliable and accurate for temperature measurement in all food environments. Housed in a robust case with built-in protective rubber boot, designed for use with a wide range of Comark probes with sub-miniature connector. The features of this Type K Food Thermometer include a permanent clock and countdown timer within the display – with selectable alarms – to allow probe insertion times to be monitored.
The case of the C28 Food Thermometer is rated to IP67 dust and waterproof standards and Comark also uses BioCote Antimicrobial Protection, the only antimicrobial solution to be awarded HACCP International Certification, to provide an important extra level of defence against cross-contamination. This product is also NSF Certified.
The C28 (C28A) Food Thermometer is a simple to use, food thermometer with Type K Thermocouple for reliable and accurate temperature measurement. It has an easy to use keypad and large LCD display. | |
The PK19M Thin Tip Penetration Probe is a Type K Thermocouple probe, fitted with a 1m curly cable. There is also BioCote Antimicrobial Protection in the probe handle to avoid the risk of cross contamination. | |
The C20WB Wall Bracket/Stand is designed for all Cxx Series Food Thermometers. It enables your Food Thermometer to be stored near to a measurement point, ready for use, or wherever convenient for operatives. |
Technical Specifications
Name | Value |
---|---|
Sensor Type | Type K Thermocouple |
Temperature Measurement Range | -200°C to +600°C / -328°F to +1112°F |
Scales | °C and °F |
Displayed Resolution | 0.1° @ > -100°, 1° @ ≤ -100° |
Instrument Accuracy | 0.1% ±0.2°C(±0.4°F) full range @ 23°C Ambient |
Temperature Coefficient | less than ±0.01 % of reading ±0.02 °C per °C (±0.04°F per °F) change from 23°C |
Ambient Temperature Range | -20°C / -4°F to +50°C / +122°F operating |
Display | 4 digit, 12.5 mm LCD |
Battery | Two Type I.E.C. LR6 Size AA |
Battery Life (continuous) | Up to 7000 hours |
Length | 152mm / 6 inches |
Width | 58mm / 2.3 inches |
Depth | 22/27mm / 0.9/1.1 inches |
Weight | 178g / 6.3 oz |
Environmental Protection | IP67 BS EN 60529 IEC 529 |
Certification | NSF Listed |
Warranty | Please refer to individual components |
*You will need to Sign In to view additional content
Documentation
Articles / FAQs
Name | Date |
---|---|
My Instrument reads OPEN (plus BAT in top of LCD)My Instrument reads OPEN (plus BAT in top of LCD)Comark ‘C’ series instruments incorporate a switch in the battery compartment to ensure that the Thermometer cannot be used if the integrity of the case is compromised and therefore ingress of liquid is possible, that could lead to damage to the battery compartment or instrument. Therefore if the Instrument reads OPEN on the Display and BAT is indicated, please ensure the battery compartment door is properly closed, by checking the following:
If OPEN message does not clear, please return for Service. | 27th July 2015 |
My Device is showing unrealistic temperature readingsMy Device is showing unrealistic temperature readingsIf you have set up your Device correctly, inserted a Sub-Miniature Connector Probe into your Device and taken a temperature reading, only to discover that the temperature recorded is vastly different to that which was expected, then it may be that the Probe Connector was in fact inserted incorrectly. The Sub-Miniature Connector on all Comark Probes has two prongs, one slightly larger than the other. These prongs are also marked as positive (+) and negative (-) on the cable head itself, as shown below. The prongs correspond to two similarly shaped slots on the Device, one slightly larger than the other. In some cases, it may be possible to force the prongs of the Sub-Miniature Cable Connector in the wrong way around. If this is done then the symptoms would be as described above, recorded temperatures that are vastly different to those which were expected. To resolve such an issue, simply unplug the Sub-Miniature Cable Connector, check the prong orientation and then re-insert.
| 4th June 2015 |
How old is my Comark Product and is it still in Warranty?How old is my Comark Product and is it still in Warranty?The serial number on most Comark Products is usually the date of manufacture followed by a unique product number. For example, 02121234 is (02) for February, (12) for year 2012, and (1234) is the number of the individual product. This works for all C series Thermometers, Evt2 and N2000 Data Loggers, RF51X Transmitters, KM2xx, PxxxFW, BTxxx etc. Warranty on most Comark Thermometers is 1 year. However, in reality Comark will give a little over the relevant warranty period to allow for distributor stock. | 21st April 2015 |
My device has corrosion in the battery compartmentMy device has corrosion in the battery compartmentThis may cause your device to cease functioning, or become dangerous. In all cases, please return your instrument to Comark for servicing. Ideally, prevention is better than cure for this problem. Check your batteries regularly to ensure they have not leaked, and if you are planning to store the instrument without use for a prolonged period, please consider removing the batteries and storing them separately. | 16th April 2015 |
- AK27M
General Purpose Air Probe
- SK42M
Surface Probe
- SK24M
Heavy Duty General Purpose Surface Probe
- SK21M
General Purpose Fast Response Surface Probe
- PK24M/US
Standard Industrial Penetration Probe (US)
- PK23M
Oven Meat Penetration Probe
- PK19M
Thin Tip Penetration Probe
- PK15M
MicroTip Penetration Probe
- ATT29
Oven and Air Probe (1.2m/4ft Lead)
- AK33M
High Temperature Air Probe (Fibreglass/1m Lead)
- AK29M
Flexible Wire Air Probe (5m Lead)
- AK28M
Flexible Wire Air Probe (1m Lead)
- SK25M
Heavy Duty Surface Probe