Replacement Battery

Part No: RFBATT (3063554)

The RFBATT is a replacement lithium battery for the temperature and humidity transmitters on your RF500 Wireless Monitoring System.

  • For RF51x Transmitter
  • Li-SOCl2 Type Battery
  • 3.6V

 

Categories: , Tag:

Replacement Battery

The RFBATT is a replacement lithium battery for the temperature and humidity transmitters on your RF500 Wireless Monitoring System.

This cylindrical primary lithium cell, based on the Lithium-Thionyl chloride (Li-SOCl2) chemistry, is perfectly suited to high-energy and high-voltage requirements in a wide range of temperature.

These batteries have a spiral construction and the cells are designed for applications requiring continuous currents in the 0.1-1.8 A range, with superimposed pulses as high as 4 A.

  • High operating voltage, stable during most of the application lifetime
  • Lowest self-discharge for extended shelf life and operating life
  • Excellent reliability over extended operating life
  • Excellent resistance to humid environments

 

Technical Specifications

NameValue
Nominal Capacity3.6 Ah
Open Circuit Voltage (At 20°C/68°F)3.67 V
Nominal Voltage (at 1mA + 20°C)3.6 V
Pulse CapabilityTypically up to 2000 mA
Maximum Recommended Continuous Current1300 mA
Storage Temperature+30°C (+ 86°F) max
Operating Temperature Range- 60 °C/+ 85°C / - 76°F/+185°F
Diameter (Max)26.0 mm (1.02 in)
Height (Max)50.4 mm (1.98 in)
Typical Weight51 g (1.8 oz)
Li Metal ContentBelow 1 g
Capacity Range1.2 Ah to 17.0 Ah
Max Pulse Discharge RateUp to 4 A

*You will need to Sign In to view additional content

Documentation

 CodeDescriptionIssue NoLast Modified
20445RF500 Wireless Monitoring Brochure023rd June 2016

Articles / FAQs

Name Date
How do I change the battery in my Transmitter?

How do I change the battery in my Transmitter?

The following information describes how to change the battery of your RF51x Transmitter.


Battery Change Procedure

The Transmitter latches any low battery condition and must be powered off fully for it to clear. You will need to wait for the display to go completely blank, in order to ensure that the low battery status has cleared. To replace the battery:

  • Disconnect all plugs from the Transmitter and remove it from its mounting bracket by sliding it upwards.
  • Locate the battery cover on the underside of the unit and using a screwdriver undo the two retaining screws, then remove the battery cover.

transmitter-battery-change

  • Remove the exhausted battery and wait a few seconds for the display to clear completely.
  • Replace the battery with a fresh (new) one, ensuring the polarity is correct and taking care to snap the new battery in cleanly, without making and breaking the contacts repeatedly.
  • Replace the battery cover and do up the two screws, taking care not to over-tighten them.
  • Observe any local restrictions on disposal of the used battery cell.

Note: All RF51x Transmitters are fitted with a high power 3.6V primary lithium-thionyl chloride C-size cell as standard.


 

Manufacturer part number: Saft LSH14 LIGHT or Saft LS26500

The Saft LS26500 battery can only be used in Transmitters manufactured after April 2009. The date-of-manufacture is encoded in the serial number of each unit. The serial number has the format MMYYxxxx where MM represents the 2-digit month and YY represents the 2-digit year in which the transmitter was manufactured. Only use Saft LSH14 LIGHT (Comark Instruments part number # RFBATT) or Saft LS26500 as replacement battery cells.


18th November 2014