OBSOLETE

HT100/PK19 HACCP Touch with PK19M Probe

Part No: HT100/PK19 (4599806)

The HT100 HACCP Touch with PK19M Probe is an easy and cost-effective device for collecting, recording and storing daily temperatures of critical items in receiving, storage, prep, cooking and holding as well as many of the other checklists you’ve been filling out by hand.

Benefits:

  • Simple paperless HACCP recording
  • Easy to navigate touchscreen interface
  • Record tasks, temperatures and corrective actions
  • Warranty: see individual components

 

This product has a newer version Visit the upgraded version.

HACCP Touch with PK19M Probe

If you are responsible for the HACCP measures in your business and still rely on paper-based control and checklists to maintain the safety of your food items and the quality of your cleaning and equipment checks, then the HT100 from Comark is for you. The HT100 HACCP Touch is your cost-effective way of electronically collecting, recording and storing all of your temperature measurements, as well as managing your other HACCP related checklists. It features an easy-to-read color touch screen and a hard-wearing rubber boot to help protect it in your tough working environment.

The HT100 can be used in-conjunction with a wide range of Comark Probes, allowing you complete flexibility and the reassurance of knowing you have the right probe for the job. The included software allows you to simply and quickly convert your existing HACCP Plans into an intuitive paperless format. Once uploaded, the HT100 will guide you through your pre-programmed actions and tasks and prompt you for any corrective actions. The HT100 will reliably store all of your HACCP data throughout the day and a simple PC connection will allow you to quickly download your data for safe storage, review and reporting, providing you with the essential reassurance needed, when it comes to your food safety audit trail.

  • Simple paperless HACCP recording
  • Critical control points are monitored with pre-programmed corrective actions
  • Record HACCP temperatures and other check lists, with pre-programmed corrective actions
  • Easy to navigate touchscreen interface
  • Record tasks, temperatures and corrective actions
  • Free easy to use Windows™ software
  • Works with all your sub-min thermocouple probes
  • Download reports as Excel or PDF
  • Rugged rubber boot included

Please Note:

To log on to the Software requires a Username and Password. The default Username is ‘Administrator’ and the default Password is ‘administrator’. Once opened there is the opportunity to change the Password, however, the default Username cannot be changed.

It is not possible for Comark to bypass the security, so please do not forget any new Password, as this will result in having to remove and re-install the Software.


Technical Specifications

NameValue
Display Type7.62 cm (3”) four color resistive touch screen
Temperature Measurement Range (Type K Thermocouple)-73°C to +537°C / -99°F to +999°F
Temperature Measurement Range (Type T Thermocouple)-73°C to +400°C / -99°F to +752°F
Operating Temperature Range0°C to +50°C / +32°F to +122°F
Storage Temperature Range-20°C to +50°C / -4°F to +122°F
Internal Resolution0.1°
Temperature Accuracy (Instrument Only)±0.5°C / ±0.9°F
HousingWater resistant with durable (Food Safe) ABS plastic rubber boot
Supported ProbesAccepts all K and T Type Thermocouple Probes with Sub-Min Connector (sold separately)
Power SupplyBattery recharged via micro USB cable (included)
Battery TypeLithium Polymer Rechargeable
Battery Life8 hours charge
Storage CapacityStore up to 65,000 readings in up to 100 separate folders for instant retrieval by date or product
Software RequirementMicrosoft Windows™ 7 or higher
WarrantyPlease refer to individual components

*You will need to Sign In to view additional content

Documentation

Downloads

 NameVersionSizeDate
HT100 Software (HT100SW)0.1.434.27 MB23rd September 2016
HT100 FirmwareB2.48220.30 KB23rd September 2016
Important Note Regarding The Upgrade of your HT10001246.50 KB27th October 2016

Articles / FAQs

Name Date
What is the default Username/Password?

What is the default Username/Password?

To log on to the Software for the HT100 HACCP Touch you will require a Username and Password.

The default Username is ‘Administrator’ and the default Password is ‘administrator’.

Once opened there is the opportunity to change the Password, however, the default Username cannot be changed.

It is not possible for Comark to bypass the security, so please do not forget any new Password, as this will result in having to remove and re-install the Software.

13th October 2017
My Device is showing unrealistic temperature readings

My Device is showing unrealistic temperature readings

If you have set up your Device correctly, inserted a Sub-Miniature Connector Probe into your Device and taken a temperature reading, only to discover that the temperature recorded is vastly different to that which was expected, then it may be that the Probe Connector was in fact inserted incorrectly.

The Sub-Miniature Connector on all Comark Probes has two prongs, one slightly larger than the other. These prongs are also marked as positive (+) and negative (-) on the cable head itself, as shown below.

Sub_Min_Right_Way_Round_c

The prongs correspond to two similarly shaped slots on the Device, one slightly larger than the other.

In some cases, it may be possible to force the prongs of the Sub-Miniature Cable Connector in the wrong way around. If this is done then the symptoms would be as described above, recorded temperatures that are vastly different to those which were expected.

Sub_Min_Wrong_Way_Round_c

To resolve such an issue, simply unplug the Sub-Miniature Cable Connector, check the prong orientation and then re-insert.

  • Small Slot = Positive
  • Large Slot = Negative

 

4th June 2015